Thread end Metal Hose
• Product
Features
Alignment absorption of heat contraction and elongation isolation of vibration.
• Applicable Conditions
Size(DN)£º DN8- DN50mm
Length£º ¡Ý200mm
Operating Pressure£º2.5MPa
Operating Temperature£º-196¡æ£450¡æ
Service£ºLiquid, gas, etc.¡£
Thread standards£ºG, NPT,PT,BS, ISo, GB,etc
• STRUCTURE
|
|
Thread end Flexible Metal Hose |
Code Type of end connection: C00 |
|
|
Code Type of end connection: Y00 |
Code Type of end connection: CY00 |
|
|
Code Type of end connection: C11 |
Code Type of end connection: Y11 |
|
|
Code Type of end connection: CY11 |
Code Type of end connection: C21 |
|
|
Code Type of end connection: Y00 |
Code Type of end connection: CY21 |
• Material
1.Bellow£ºStainless
steels 304 316L 321 254 309 Inconel625 31803 etc
2.Braided£º Stainless steels201,202,304,321,316 etc
3.Ball Joint£ºCarbon steel, Stainless steels, etc
• The
product code consists of following
elements¡¡
•
Guides for Flexible Metal Hose installation
1. The Flexible Metal Hose shall
be installed according to the engineering drawing of pipe line and the
Flexible Metal Hose installations
2. In order to insure proper function of any expansion joints, it is necessary
that all pipe lines in which expansion joints are located be suitably
guided and anchored. The guides and anchors must be installed strictly
in accordance to relevant technical documentation. Please refer to the
¡°guideline for installation of Expansion Joints¡± about the principle of
using guides and anchors.
3. Since the bellows used in expansion joints are made of thin stainless
steel sheets, special attention shall be paid when transporting, handing
and welding to avoid damage of bellows caused by dents, scores, arc strikes
and weld spatters.
4. Any foreign laterals in the bellows and pipes shall be removed to ensure
the proper function of expansion joints before installation.
5. If the flow direction is specified, be sure to install expansion joint
with the proper orientation with the respect of flow direction arrow.
6. No movement of the expansion joint (such as axial compression or extension,
lateral offset, or rotation) due to piping misalignment shall be imposed
during installation so as to ensure proper function of the bellows.
• Date
sheet |